Components
Every component, running. Click around, then open one for its code.
44 components
Actions2
- ButtonTriggers an action. One primary button per view marks the action that matters most.
- Toggle and segmented controlA pressed/unpressed button, and a segmented control for a few mutually exclusive modes.Step responseR-0412 · Bench 3
0–400 ms: peaks 17.6 % over at 61 ms, settles by 182 ms.
Inputs5
- InputA single-line text field. Aligns with buttons and selects of the same size.
Reported by the controller.
Locked while R-0412 is running.
There is no Bench 9. Enter a bench from 1 to 6. - FieldGroups a label, a control, help text and an error, and wires their ids for assistive tech.
Overshoot and settling time are compared against this run.
- Input groupA text field with an icon, unit, keyboard hint or small button inside its border./N·mms
- TextareaMulti-line text that grows with its content, then scrolls.
Reviewers see this on R-0412.
125/600 - Number fieldA number with steppers, a unit and a scrubbable label. Formats with the user’s locale.N·mms
Drag a label sideways to scrub. Arrow keys step; Shift + arrow takes a larger step.
Selection6
- SelectChoose one option from a list. The popup aligns the selected item over the trigger, as macOS does.
The command the bench applies to the actuator.
- ComboboxA searchable select for long lists, with a clear button and an explicit empty state.
12 actuators on the walking rig.
- CheckboxTurns an independent option on or off, including an indeterminate “some selected” state.
- Radio groupOne choice from a short list that stays visible.Settling criterion
Settled once the response stays within 2 % of the setpoint.
Looser. Use for loaded or compliant joints.
Settled when joint speed stays under 0.05 rad/s for 50 ms.
- SwitchAn on/off setting that takes effect immediately.
Bench 3 is streaming torque and current at 1 kHz.
Cuts motor power when a winding passes 85 °C.
Locked while R-0412 is running.
- SliderA value on a continuous track; pass two values for a range.15 %
R-0412 peaked at 17.6 %: flagged for review.
120–680 msSettling time and overshoot are computed inside this window.
Overlays8
- DialogA modal task. Focus moves in, the page behind is inert, Escape closes and focus returns to the trigger.
- Alert dialogConfirms a destructive or irreversible action; clicking outside does not dismiss it.
- SheetA panel that slides in from an edge and can be swiped away: inspectors, edit forms, mobile navigation.
- R-0410 · Nominal step
- R-0411 · Damped step
- R-0412 · High-gain step
- PopoverNon-modal content anchored to its trigger: filters, quick settings, details.Overshoot ≤ 15 %, settling ≤ 250 ms
- TooltipA short label for an icon-only control. After the first, neighbours open instantly.traces/bench-3/R-0412_high-gain-step_torque.csv
- MenuActions or options behind a trigger, with groups, checkable items, submenus and shortcuts.R-0412 · High-gain stepBench 3 · overshoot 17.6 %
- Command paletteA ⌘K palette to jump anywhere and run any command. Opens instantly, no animation.
- ToastA brief confirmation that stacks, expands on hover, pauses when hidden and swipes away.
Navigation1
- TabsSwitches between views of the same object, as a segmented control or an underline.
- Overshoot
- 17.6 %
- Settling time
- 186 ms
- Peak torque
- 9.41 N·m
- Winding temperature
- 71.2 °C
Feedback4
- AlertAn inline message about the current view: what happened and what to do next.Traces for R-0412 did not loadBench 3 stopped responding during the download. The run itself was saved.Winding temperature is near its limitThe motor reached 84 °C of 90 °C. Let it cool to 40 °C before the next high-gain step.Bench 3 now runs firmware 4.18.2Runs from before the update are compared against the old reference, R-0409.Gains approvedKp 3.60 and Kd 0.09 passed all five acceptance checks on R-0413.
- Empty stateWhat to show when there is nothing to show, with the reason and the next step.
No runs on Bench 3 yet
Run a step test to record torque, phase current and winding temperature.
No runs match these filters
No failed runs on firmware 4.18.2 in the last 7 days.
- Progress and meterProgress shows task completion; Meter shows a measurement against its range and limit.
Progress: work getting done
Uploading R-0412 tracesComputing efficiency mapMeter: a measurement against its limit
Winding temperaturePhase currentNear the 40 A limit
- Spinner and skeletonAn Apple-style activity indicator, and placeholders shaped like the content that is loading.
Recent runs
Fetching runs from Bench 3…
Data display7
- BadgeA short status or category label. Status always carries a word, never color alone.
Run results: an icon and a word, never color alone
FailedNear limitPassedRunningQueuedCategories
Bench 3Firmware 4.18.2High-gain stepReferenceStatus dots in a dense list, always with a label
- Bench 1Idle
- Bench 2Running R-0413
- Bench 3Over temperature
- CardA grouped surface with header, content and footer. Depth from a lighter fill and a hairline.
Torque step response
R-0412 against the R-0409 reference, in N·m
- R-0412 measured
- R-0409 reference
- Over limit
Use the left and right arrow keys to read values. Hold Shift for larger steps.Bench 3 · firmware 4.18.2 · captured at 1 kHz - MetricA measurement with its unit, a meter against its limit and a status that pairs an icon with a word.Overshoot17.6%FailLimit 10 %Settling time186msNear limitLimit 200 msPhase current31.2APassLimit 40 AWinding temp.71.2°CPassLimit 90 °CSteady-state error0.4%PassLimit 2 %
- TableA semantic data table with right-aligned tabular numbers, selection and contained horizontal scroll.
Bench 3, firmware 4.18.2. Selected: R-0412. Run Profile Result Kp Overshoot (%) Settling (ms) Peak torque (N·m) R-0412 High-gain step Failed 4.20 17.6 186 9.41 R-0411 High-gain step Failed 3.90 11.2 174 8.90 R-0410 Fast rise Near limit 3.60 7.9 192 8.63 R-0409 Nominal step Passed 3.20 3.8 158 8.30 R-0408 Nominal step Passed 3.20 6.8 161 8.54 R-0407 Damped step Passed 2.80 5.2 149 8.42 - AvatarA person or team, falling back to correct initials (graphemes, suffixes, emoji) when there is no image.
- MOMaya OkaforOwner, R-0412
- JLJonas Lindqvist Jr.Reviewer
- ÉMÉlodie MarchandApprover, gains
MOJLÉMSÅ5 reviewers on the Bench 3 retune - KbdA keyboard key or shortcut with platform glyphs.
Press ⌘K to jump to any run on Bench 3.
- Search runs and commands
- ⌘K
- Next run
- J
- Previous run
- K
- Show or hide the reference trace
- ⇧R
- Export the visible traces as CSV
- ⌘⇧E
- AccordionSections that expand in place. Good for FAQs and secondary settings.The peak torque above the commanded step, as a percentage of the step. R-0412 peaked at 9.41 N·m on an 8.0 N·m step: 17.6 %. The limit is 10 %.
Layout3
- App shellThe frame of a product: translucent sidebar, sticky toolbar, page header; the sidebar becomes a sheet on phones.
Needs review / R-0412 Bench 3 · firmware 4.18.2R-0412 High-gain step
Overshoot reached 17.6 %, past the 10 % limit. Settling took 186 ms.FailedKp 4.20- Peak torque
- 9.41 N·m
- Phase current
- 31.2 A
- Winding temperature
- 71.2 °C
- SeparatorA hairline between groups, for when spacing alone does not separate them.
Gains
- Kp
- 4.20
- Ki
- 0.80
- Kd
- 0.12
Limits
- Overshoot
- 10 %
- Settling time
- 200 ms
- Winding temperature
- 90 °C
- Scroll areaA scroll container with overlay scrollbars and edge fades only where content overflows.
R-0412 event log
Charts8
- Line chartEngineering traces with limits, bands, markers, a synced crosshair, keyboard reading and downsampling.
Torque step response
Torque in N·m · Bench 3 · 8.0 N·m step · 1 kHz
- R-0412 measured
- R-0409 reference
- Command
- ±2 % settling band
- Over limit
Use the left and right arrow keys to read values. Hold Shift for larger steps. - Bar chartComparison across a few categories; bars past the limit turn critical so the outlier reads first.
Overshoot per run
Overshoot in % · Bench 3 · runs R-0405 to R-0412
- HeatmapA sequential map over two axes, such as motor efficiency over speed and torque.
Motor efficiency map
Hip-pitch actuator · firmware 4.18.2 · Bench 3
Efficiency6595 % - SparklineA word-sized trend with an emphasized endpoint.
Overshoot over the last 12 runs on Bench 3. Limit 10 %. Joint Trend Latest Hip pitch 17.6 %, over the limit Knee 4.9 % Ankle 3.7 % - Stream chartA live time series for telemetry: newest sample at the right edge, limits, and anything past a limit in red.Live torqueRA-14 hip pitch · Bench 3 · 1 kHzA live chart. The latest values are listed above it; crossing a limit is announced.
- Command
- – N·m
- Measured
- – N·m
- Frequency chartFrequency response on a log axis: a spectrum, or a Bode plot with gain and phase margins drawn where they are measured.Open-loop responseRA-14 hip pitch · R-0412 against the R-0409 referenceUse the left and right arrow keys to read values by frequency. Hold Shift for larger steps.
- Scatter chartThe relationship between two measurements across many runs, with limits, a fit line and one point called out.Gain against overshootRA-14 hip pitch · 412 step testsUse the arrow keys to move between points from left to right. Hold Shift for larger steps.
- Over limit12
- Within limit400
- HistogramA distribution against specification limits, with n, mean, standard deviation and Cpk stated in words.Overshoot across all runsRA-14 hip pitch · Bench 3 · since firmware 4.16Use the arrow keys to move between bins. Hold Shift for larger steps.
- n
- 412
- Mean
- 5.6 %
- σ
- 2.5 %
- Cpk
- 0.60 · not capable