RA-14 hip pitchBench 3Firmware 4.18.218 Nov 2026, 14:32

R-0412High-gain step

1 failed1 near limit
Overshoot17.6%FailLimit ≤ 10 %
Peak current30.9ANear limitLimit ≤ 32 A
Settling, 2 %203msPassLimit ≤ 250 ms
Rise, 10–90 %40msPassLimit ≤ 80 ms
Winding temp71°CPassLimit ≤ 90 °C

Step response

Torque command 0 → 12 N·m at 20 ms, against the last passing run

  • R-0412 measured
  • R-0409 reference
  • Command
  • ±2 % settling band
  • Over limit
Output torque, N·m
Use the left and right arrow keys to read values. Hold Shift for larger steps.
Phase current, A
Use the left and right arrow keys to read values. Hold Shift for larger steps.
Sampled at 1 kHz · load cell and phase shunt, Bench 3

Run history

RA-14 hip pitch, last 8 runs

RunProfileOvershootResultActions
R-0412High-gain step17.6 %Fail
R-0411High-gain stepKd 0.0421.3 %Fail
R-0410Mid-gain step9.1 %Review
R-0409Nominal stepreference3.9 %Pass
R-0408Damped step1.2 %Pass
R-0407Fast rise12.4 %Fail
R-0406Thermal soak, 20 min3.9 %Review
R-0405Nominal step3.6 %Pass